Radial Centrifugal Blower, Multi-Drive, Fine Particulate Material Handling

Industrial Blower M

High-efficiency material handling fan featuring heavy or ultra-heavy housing construction, multiple arrangements, belt or direct drive, and a wide range of optional upgrades. For material handling applications.

Industrial Material Handling
Aggressive, Abrasive Particulate Duty
11 Models, 440 to 39,277 CFM, Max 20" SP
Arrangement 1, 4, 8, 9 and 10 SWSI

Industrial Blower M

Capability

Common Applications

Material Handling and Dirty Air Applications: Saw Dust Transfer, Grain Conveyance, Industrial Dusty / Particulate-Laden Air or Gas Exhaust.

Airflow

Small Particulate Material Handling and Dirty Air from 440 CFM to 39,277 CFM, up to 20" SP.

Size Format

AMCA Arrangement 1, 4, 8, 9, and 10 SWSI: Single Width Single Inlet.

Wheel

Steel Flat Radial Blade Wheel. Diameters 15.625" to 57.5".

Drive

By Arrangement, Direct Drive or Fixed/Adjustable Pitch V-Belt Sheave Drive. Premium Efficiency, 120 to 480VAC Single or Three Phase, NEMA Enclosure and Frame Size Motors.

Temperatures

Steel Wheel: 600°F max at full airflow capacity, 700°F max at 85% derated capacity, 800°F max at 70% derated capacity. Aluminum Wheel option: 150°F max at full airflow capacity, 200°F max at 95% derated capacity, 250°F max at 80% derated capacity.

Inlet

Circular Inlet Ring Diameter 9.25" to 33.375". Optional Flanged Inlet.

Outlet

Rectangular Outlet 9" H x 7.5" W to 33" H x 26.5" W. Optional Outlet Flange.

Construction

Steel Sheet, Gray Powder-Coated Finish. Indoor / Outdoor, Heavy-Duty.

Spark Resistance

Optional AMCA Spark A, B, or C Resistant Construction.

Approvals

ISO-9001 Certified Shop. AMCA Accredited In-House Test Laboratory.

Industrial Blower M

Available Models

Model

M-09

M-11

M-13

M-15

M-17

M-19

M-21

M-23

M-26

M-29

M-33

Wheel Diameter

15 5⁄8

19 1⁄8

22 5⁄8

26 1⁄8

29 5⁄8

33

36 1⁄2

40

45 1⁄8

50 1⁄2

57 1⁄2

Max CFM

2904

4336

6059

8065

10362

12943

15906

19074

24380

30334

39277

Max SP

20

20

20

20

20

20

20

20

20

20

20

Max BHP

17.36

25.93

36.21

48.21

61.92

77.35

89.38

107.22

137.01

170.46

220.72

Inlet Area Sq. Ft.

0.44

0.66

0.92

1.23

1.58

1.97

2.4

2.88

3.59

4.59

5.94

Outlet Area Sq. Ft.

0.44

0.66

0.92

1.22

1.57

1.96

2.41

2.89

3.69

4.6

5.95

Max RPM

Standard Duty

Heavy Duty

4287

4523

3508

3693

2968

3125

2572

2705

2270

2384

2031

2141

1855

1935

1694

1767

1498

1566

1343

1399

1181

1229

Shaft Diameter

Standard Duty

Heavy Duty

1 3⁄16

1 7⁄16

1 7⁄16

1 11⁄16

1 11⁄16

1 15⁄16

1 15⁄16

2 3⁄16

1 15⁄16

2 3⁄16

2 3⁄16

2 7⁄16

2 7⁄16

2 11⁄16

2 11⁄16

2 15⁄16

2 11⁄16

3 7⁄16

2 15⁄16

3 7⁄16

3 7⁄16

3 15⁄16

Fan Selection Tool

Our online fan selection tool will help you identify a suitable model for your application's requirements.

Industrial Blower M

Construction

Featuring heavy-gauge housings, direct or belt drives, lip and flange ducting connections, and fully welded frames, our Peerless' Industrial Blower M series can tackle any small-particulate airstream application.

Wheel

Heavy gage steel, straight radial blade design that self-cleans during use, maintaining its balance and assuring efficient airflow even in particulate-heavy conditions.

Heavy-Duty Steel.
Dynamically Factory Balanced.
Self-Cleaning Design.
18,500 FPM Wheel Tip Max Speed with Shaft and Bearing Upgrades.

Frame

Indoor/outdoor, open-member steel frames with pedestal motor mounts keep drivetrains and wheels in alignment longer than formed sheet frames, resulting in longer maintenance intervals.

Fully-Welded Steel Frame.
Easy Maintenance Access.
Fewer Alignment Adjustments Needed.

Housing

All fan housings can be fully rotated to reposition the discharge at any of the pre-drilled intervals, allowing for a wide range of installation and ducting configurations. Housing rotation does not require rebalancing.

Factory or Field Repositioning.
M-09 to M-17 have 22.5° Intervals.
M-19 to M-23 have 15° Intervals.
M-26 to M-33 have 11.25° Intervals.

Connections

Depending on the Arrangement specified, inlet and discharge ducting flange or ducting lip connections are available. See product literature for each model's standard connections.

Ducting Flange and Lip Connection.
Check Literature for Standard Connections by Model.

Finish

Standard paint finish is a baked polyester coating over phosphatize-cleaned steel materials.

Highly Durable Polyester Coating.
Steel is Cleaned and Prepped Prior to Coating.
High Abrasion Resistance for Long Life.

Drive System

Configure as either an adjustable pitch V-belt or direct drive, with heavy-duty motor base rails, ground and polished keyed shafts, and self-aligning normal duty bearings.

V-Belt or Direct Drive.
Factory-Set RPM Available.
Single Speed, TEFC, Inverter Duty Motor.
100K Run Hour Bearings.

Industrial Blower M

Arrangements

Peerless' Industrial Blower M series is available in Arrangement 1, 4, 8, 9, and 10 SWSI.

Arrangement 1 SWSI

AMCA Arrangement 1 SWSI features dual bearings mounted on a base frame, with an overhung fan impeller for use with belt or direct drives. For belt drive configurations, motor positions W, X, Y, and Z are available. Motor supports can be provided in the field or at the factory.

V-Belt Drive with Overhung Impeller.
SWSI Type: Single Width Single Inlet.
Normal Duty, 100k Run Hour Bearings.
Remote Mounted Motor.

Arrangement 4 SWSI

AMCA Arrangement 4 SWSI utilizes a direct-drive motor mounted onto a base frame, attached to the fan housing. The fan impeller is overhung on the motor shaft and does not need separate bearings.

Direct Drive with Overhung Impeller.
SWSI Type: Single Width Single Inlet.
No Bearings on Fan.
Onboard Motor.

Arrangement 8 SWSI

AMCA Arrangement 8 SWSI is comparable to Arrangement 1, however adds a separate motor pedestal at the end of the impeller shaft, allowing for a direct drive installation coupled with dual external bearings.

Direct Drive with Overhung Impeller.
SWSI Type: Single Width Single Inlet.
Normal Duty, 100k Run Hour Bearings.
Onboard, Pedestal-Mount Motor.

Arrangement 9 SWSI

AMCA Arrangement 9 SWSI utilizes dual bearings mounted on a base frame, with an overhung fan impeller for use with belt drives. The motor is mounted outside of the frame or pedestal.

V-Belt Drive with Overhung Impeller.
SWSI Type: Single Width Single Inlet.
Normal Duty, 100k Run Hour Bearings.
Onboard Motor.

Arrangement 10 SWSI

AMCA Arrangement 10 SWSI features a space-efficient, packaged design with an onboard motor mounted within the fan's bearing pedestal.

V-Belt Drive with Overhung Impeller.
SWSI Type: Single Width Single Inlet.
Normal Duty, 100k Run Hour Bearings.
Onboard Motor.

Industrial Blower M

Options

Peerless' Industrial Blower M series is designed for small particulate material handling, and the below options can further improve safety and performance in your application.

Upgraded Heavy-Duty Construction

For exceptionally abrasive material handling conditions, the Industrial M series offers an upgrade to increase housing and wheel metal thicknesses, shaft diameter, and bearing duty.

For Extremely Abrasive Applications.
Thicker Housing and Wheel Materials.
15,000 FPM Wheel Tip Max Speed.

Weather Cover

The solid sheet metal Weather Cover installs over the belt drive and motor frame, offering weather protection without the need of a separately constructed penthouse or canopy.

Eliminates Separate Canopy Cover.
Solid Metal Protection.
Removable for Maintenance.

Belt Guard

Our heavy-duty Belt Guard is fabricated from expanded metal and installed over the V-belt drive end of the fan, providing personnel protection from the drive's moving parts.

Added Personnel Protection.
Covers All Rotating Parts.

Vibration Rails

For sound and vibration sensitive applications, Peerless can provide spring or rubber-in-shear Vibration Isolation Rails and Isolation Pads.

Reduces Acoustical Impact.
​Isolates Vibration.

Automatic Outlet Damper

Protecting the fan from backdrafts, rain, and snow, our corrosion-resistant Outlet Damper securely attaches to the fan outlet. Choose from automatic, motorized, or manual operation. Outlet dampers are not available with mesh screens.

Protects Against Backdrafts.
Holds Weather Out.
Corrosion Resistant.

Anti-Corrosion Finishes

To help protect against the abuse of particulates, greases, and acids, Anti-Corrosion Paint and Finish options can avoid premature housing damage in very aggressive applications.

Combats Very Aggressive Applications.
Prevents Premature Failure.
Ideal for Acids and Greases.

Spark Resistance

For applications where hazardous gases or other ignitable conditions exist, Peerless offers fully Spark-Resistant Construction and explosion-proof motors per AMCA Spark A, B, and C hazard classifications.

​​Hazardous Condition Protection.
AMCA Spark A, B, C.
Explosion Proof Motors.

Motors

Peerless can provide nearly any special motor specification, including multi-speed windings, stainless steel casings, washdown and other environmental ratings, inverter duty, explosion proof, IEC and other frame sizes, and more.

Any Compatible Motor Can Be Provided.
Domestic or International Frames.
Special Environment Ratings.

Stay In Touch!