KE Radial Blower Peerless

KE | Radial Blower

The Peerless Blowers KE | Radial Blower is a low pressure, low volume air blower featuring a self-cleaning radial flat blade wheel, direct drive motor, configurable rotation, and multiple outlet orientations.

It is suitable for dirty air exhaust applications.

  • Small, Industrial Applications
  • High pressure capabilities
  • 5 Models, 93 to 3,393 CFM, Max 2.25" SP
  • Low Pressure Capabilities
  • Arrangement 4 SWSI

Technical Specifications

Applications

Dirty Air, Small Commercial and Industrial, Low-Pressure Applications:

  • Kitchen Hood Exhaust
  • Laundry Exhaust
Capabilities
  • COMMON APPLICATIONS: Dirty Air, Small Commercial and Industrial, Low-Pressure Applications: Kitchen Hood Exhaust, Laundry Exhaust.
  • AIRFLOW: Dirty Air from 93 CFM to 3,393 CFM, up to 2.25" SP.
  • SIZE FORMAT: AMCA Arrangement 4 SWSI: Single Width Single Inlet.
  • WHEEL: Cast Aluminum Wheel with Straight, Flat Self-Cleaning Radial Blades. Diameters 7.75" to 13.5".
  • DRIVE: Direct Drive. Premium Efficiency, Fixed or Variable Speed, 120 to 480VAC Single or Three Phase, NEMA Enclosure and Frame Size Motors.
  • TEMPERATURES: 150°F Max.
  • INLET: Circular Inlet Ring Diameter 8" to 14.5".
  • OUTLET: Rectangular Outlet 8.25" H x 5.375" W to 14.625" H x 10.75" W.
  • CONSTRUCTION: Steel Sheet, Gray Powder-Coated Finish. Indoor / Outdoor, Heavy-Duty.
  • SPARK RESISTANCE: Optional AMCA Spark A, B, or C Resistant Construction.
  • ​​APPROVALS: AMCA Certified Performance on KE Models. ISO-9001 Certified Shop. AMCA Accredited In-House Test Laboratory.
Available Models
MODEL WHEEL DIAMETER [in] MAX CFM MAX SP [in WG] MAX BHP INLET AREA [sqf] OUTLET AREA
[sqf]
RPM SHAFT DIAMETER [in]
KE-8 7 3⁄4 533 3⁄4 1⁄6 0.34 0.3 1725 1⁄2
KE-9 9 909 3⁄4 1⁄4 0.44 0.48 1725 1⁄2
KE-11 10 7⁄8 1593 1 1⁄2 3⁄4 0.54 0.65 1725 5⁄8
KE-12 12 1⁄2 2461 2 1 1⁄2 0.95 0.88 1725 5⁄8
KE-14 13 1⁄2 3393 2 1⁄4 2 1.14 1.09 1725 7⁄8
Construction

Designed and built for dusty, gritty, and particulate-carrying airstreams at low pressures, Peerless' Radial Blower KE series easily handles your most challenging dirty air demands.

Wheel
Heavy cast aluminum, straight radial blade design that self-cleans during use, maintaining its balance and assuring efficient airflow even in particulate-heavy conditions.

  • Heavy-Duty Cast Aluminum.
  • Dynamically Factory Balanced.
  • Self-Cleaning Design.
  • High Efficiency.

Housing
All fan housings can be fully rotated to reposition the discharge at any of eight pre-drilled 45° intervals, allowing for a wide range of installation and ducting configurations.

  • 45° Rotation Intervals.
  • Factory or Field Repositioning.
  • Housing Rotation Does Not Require Rebalancing.

Rotation
Standard clockwise wheel rotation, bottom horizontal discharge position. Other rotations and discharge orientations can be supplied upon request.

  • ​​Clockwise Wheel Rotation Standard.
  • Optional Counter-Clockwise Wheel Rotation.

Frame
Indoor/outdoor, open-member steel frames keep motors, drivetrains, and wheels in alignment longer than formed sheet frames, resulting in longer maintenance intervals.

  • Fully-Welded Steel Frame.
  • Easy Maintenance Access.
  • Fewer Alignment Adjustments Needed.

Drive System
Direct drive, open ball bearing motors are fixed-mounted onto a welded base frame. No belt tensioning or bearing adjustments are necessary.

  • Factory-Set RPM Available.
  • Multiple Motor Options.
  • Explosion Proof Motor Options.
Arrangements

Peerless' Radial Blower KE series is available in Arrangement 4 SWSI.

Arrangement 4 SWSI
AMCA Arrangement 4 SWSI utilizes a direct-drive motor mounted onto a base frame, attached to the fan housing. The fan impeller is overhung on the motor shaft and does not need separate bearings.

  • Direct Drive with Overhung Impeller.
  • SWSI Type: Single Width Single Inlet.
  • No Bearings on Fan.
  • Onboard Motor.
Options

With extreme applications in mind, the Peerless' Radial Blower KE series offers multiple options to extend the fan's service life even in aggressive particulate and soil conditions.

Weather Cover
The solid sheet metal Weather Cover installs over the drive and motor, offering weather protection without the need of a separately constructed penthouse or canopy.

  • Eliminates Separate Canopy Cover.
  • Solid Metal Protection.
  • Removable for Maintenance.

Vibration Rails
For sound and vibration sensitive applications, Peerless can provide spring or rubber-in-shear Vibration Isolation Rails and Isolation Pads.

  • Reduces Acoustical Impact.
  • ​Isolates Vibration.

Automatic Outlet Damper
Protecting the fan from backdrafts, rain, and snow, our corrosion-resistant Outlet Damper securely attaches to the fan outlet. Choose from automatic, motorized, or manual operation. Outlet dampers are not available with mesh screens.

  • Protects Against Backdrafts.
  • Holds Weather Out.
  • Corrosion Resistant.

Anti-Corrosion Finishes
To help protect against the abuse of particulates, greases, and acids, Anti-Corrosion Paint and Finish options can avoid premature housing damage in very aggressive applications.

  • Combats Very Aggressive Applications.
  • Prevents Premature Failure.
  • Ideal for Acids and Greases.

Spark Resistance
For applications where hazardous gases or other ignitable conditions exist, Peerless offers fully Spark-Resistant Construction and explosion-proof motors per AMCA Spark A, B, and C hazard classifications.

  • Hazardous Condition Protection.
  • AMCA Spark A, B, C.
  • Explosion Proof Motors.

Motors
Peerless can provide nearly any special motor specification, including multi-speed windings, stainless steel casings, washdown and other environmental ratings, inverter duty, explosion proof, IEC and other frame sizes, and more.

  • Any Compatible Motor Can Be Provided.
  • Domestic or International Frames.
  • Special Environment Ratings.

Downloads

Heritage Products Catalogs | Centrifugal Radial Pressure Blowers KE, PW

Centrifugal Radial Pressure Blowers | KE

Sign in to download

Fan Selector

Our online fan selection tool will help you identify a suitable model for your application's requirements and let you create a submittal.

Start Fan Selection

Contact our Sales Team

Mitarbeiterbild

Frank Mueller

Director of Sales - Americas

Phone:
+1.828.270.0343
Mobile:
+1.828.855.5446
E-Mail:
frank.mueller@punker.com

Mitarbeiterbild

T.J. King

Senior Sales Manager

Phone:
+1.828.622.7500
Mobile:
+1.828.206.1512
E-Mail:
TJKing@PeerlessBlowers.com

Mitarbeiterbild

Lisa Elkins

Inside Sales Manager

Phone:
+1.828.622.7500
E-Mail:
LElkins@PeerlessBlowers.com

Mitarbeiterbild

Heather Sawyer

Inside Sales Manager

Phone:
+1.828.622.7500
E-Mail:
HSawyer@PeerlessBlowers.com

Mitarbeiterbild

Gary Smith

Territory Sales Manager - Northeast

Phone:
+1.828.622.7500
Mobile:
+1.404.693.0052
E-Mail:
GSmith@PeerlessBlowers.com

Mitarbeiterbild

Joshua Meares

Area Sales Manager - Southwest

Mobile:
+1.980.342.0432
E-Mail:
joshua.meares@peerlessblowers.com

Mitarbeiterbild

Michael Burdukovsky

Area Sales Manager - Southeast USA

Phone:
+1.828.622.7500
Mobile:
+1.980.342.0941
E-Mail:
Michael.Burdukovsky@PeerlessBlowers.com

Mitarbeiterbild

Edgardo Rojas

Sales Representative - Mexico

Phone:
+52.442.595.8285
E-Mail:
edgardo.rojas@punker.com

Contact Us!

I hereby consent to the storage and processing of my personal data. I have read and taken note of the following information on the processing of my personal data and on data protection.