Radial Centrifugal Blower, Direct Drive, Low Pressure
Radial Blower KE
Low pressure, low volume air blower featuring a self-cleaning radial flat blade wheel, direct drive motor, configurable rotation, and multiple outlet orientations. For dirty air exhaust applications.
Radial Blower KE
Capability
Common Applications
Dirty Air, Small Commercial and Industrial, Low-Pressure Applications: Kitchen Hood Exhaust, Laundry Exhaust.
Airflow
Dirty Air from 93 CFM to 3,393 CFM, up to 2.25" SP.
Size Format
AMCA Arrangement 4 SWSI: Single Width Single Inlet.
Wheel
Cast Aluminum Wheel with Straight, Flat Self-Cleaning Radial Blades. Diameters 7.75" to 13.5".
Drive
Direct Drive. Premium Efficiency, Fixed or Variable Speed, 120 to 480VAC Single or Three Phase, NEMA Enclosure and Frame Size Motors.
Temperatures
150°F Max.
Inlet
Circular Inlet Ring Diameter 8" to 14.5".
Outlet
Rectangular Outlet 8.25" H x 5.375" W to 14.625" H x 10.75" W.
Construction
Steel Sheet, Gray Powder-Coated Finish. Indoor / Outdoor, Heavy-Duty.
Spark Resistance
Optional AMCA Spark A, B, or C Resistant Construction.
Approvals
AMCA Certified Performance on KE Models. ISO-9001 Certified Shop. AMCA Accredited In-House Test Laboratory.
Radial Blower KE
Available Models
Fan Selection Tool
Our online fan selection tool will help you identify a suitable model for your application's requirements.
Radial Blower KE
Construction
Designed and built for dusty, gritty, and particulate-carrying airstreams at low pressures, Peerless' Radial Blower KE series easily handles your most challenging dirty air demands.
Wheel
Heavy cast aluminum, straight radial blade design that self-cleans during use, maintaining its balance and assuring efficient airflow even in particulate-heavy conditions.
Housing
All fan housings can be fully rotated to reposition the discharge at any of eight pre-drilled 45° intervals, allowing for a wide range of installation and ducting configurations.
Rotation
Standard clockwise wheel rotation, bottom horizontal discharge position. Other rotations and discharge orientations can be supplied upon request.
Frame
Indoor/outdoor, open-member steel frames keep motors, drivetrains, and wheels in alignment longer than formed sheet frames, resulting in longer maintenance intervals.
Drive System
Direct drive, open ball bearing motors are fixed-mounted onto a welded base frame. No belt tensioning or bearing adjustments are necessary.
Radial Blower KE
Arrangements
Peerless' Radial Blower KE series is available in Arrangement 4 SWSI.
Arrangement 4 SWSI
AMCA Arrangement 4 SWSI utilizes a direct-drive motor mounted onto a base frame, attached to the fan housing. The fan impeller is overhung on the motor shaft and does not need separate bearings.
Radial Blower KE
Options
With extreme applications in mind, the Peerless' Radial Blower KE series offers multiple options to extend the fan's service life even in aggressive particulate and soil conditions.
Weather Cover
The solid sheet metal Weather Cover installs over the drive and motor frame, offering weather protection without the need of a separately constructed penthouse or canopy.
Vibration Rails
For sound and vibration sensitive applications, Peerless can provide spring or rubber-in-shear Vibration Isolation Rails and Isolation Pads.
Automatic Outlet Damper
Protecting the fan from backdrafts, rain, and snow, our corrosion-resistant Outlet Damper securely attaches to the fan outlet. Choose from automatic, motorized, or manual operation. Outlet dampers are not available with mesh screens.
Anti-Corrosion Finishes
To help protect against the abuse of particulates, greases, and acids, Anti-Corrosion Paint and Finish options can avoid premature housing damage in very aggressive applications.
Spark Resistance
For applications where hazardous gases or other ignitable conditions exist, Peerless offers fully Spark-Resistant Construction and explosion-proof motors per AMCA Spark A, B, and C hazard classifications.
Motors
Peerless can provide nearly any special motor specification, including multi-speed windings, stainless steel casings, washdown and other environmental ratings, inverter duty, explosion proof, IEC and other frame sizes, and more.