PVI Propeller Fan Peerless

PVI Propeller Fan | Axial Propeller Fan

The Peerless Blowers PVI Propeller Fan | Axial Propeller Fan is an Industrial-grade with multi-speed axial propeller fan featuring an adjustable belt drive, serviceable long-life bearings, welded steel frames, and continuous-duty motors.

It is suitable for clean air applications.

  • Industrial-Duty Ventilation
  • Many Special Application Options
  • 7 Models, 4,800 to 63,445 CFM, Max 1.0" SP
  • Heavy-Duty Mounting Panel

Technical Specifications

Applications

Clean Air, Industrial Ventilation Applications:

  • Steel Mills
  • Machine Shops
  • Manufacturing Plants
  • Packaging Warehouses
Capabilities
  • AIRFLOW: Clean Air from 4,800 CFM to 63,445 CFM, up to 1.0" SP. 
  • SIZE FORMAT: Panel Mount. 
  • PROPELLER: Axial Propeller, Steel Blades. Diameters 24" to 60". 
  • DRIVE: Fixed or Adjustable Pitch V-Belt Sheave Drive. High Efficiency, TEAO, 120 to 480VAC Single or Three Phase, NEMA Frame Size Motors. Single or Dual Speed. 
  • TEMPERATURES: 40°C / 104°F Max. 
  • INLET: Square Mounting Panel 34" H x 34" W to 66" H x 66" W. 
  • OUTLET: Circular Through-Panel Outlet. 
  • CONSTRUCTION: Steel Sheet, Gray Powder-Coated Finish. Heavy-Duty. 
  • SPARK RESISTANCE: Not available for this series. 
  • ​​APPROVALS: ISO-9001 Certified Shop. AMCA Accredited In-House Test Laboratory. 
Available Models
MODEL PROP DIAMETER [in] MAX CFM MAX SP [in WG] MAX BHP PANEL LENGTH [in] PANEL WIDTH [in] MOTOR HP RPM
PVI-24C 24 5890 1⁄8 0.4 34 34 1⁄3 865
PVI-24D 24 6700 1⁄4 0.6 34 34 1⁄2 991
PVI-24E 24 7700 3⁄8 0.9 34 34 3⁄4 1134
PVI-24F 24 8500 1⁄2 1.2 34 34 1 1248
PVI-24G 24 9690 5⁄8 1.8 34 34 1 1⁄2 1429
PVI-30D 30 8418 1⁄4 0.6 40 40 1⁄2 730
PVI-30E 30 9636 3⁄8 0.9 40 40 3⁄4 835
PVI-30F 30 10606 1⁄2 1.2 40 40 1 920
PVI-30G 30 12140 5⁄8 1.8 40 40 1 1⁄2 1052
PVI-30H 30 13362 3⁄4 2.4 40 40 2 1158
PVI-36E 36 11000 1⁄4 0.9 46 46 3⁄4 526
PVI-36F 36 12100 3⁄8 1.2 46 46 1 579
PVI-36G 36 13850 1⁄2 1.8 46 46 1 1⁄2 663
PVI-36H 36 15210 5⁄8 2.4 46 46 2 729
PVI-36J 36 17300 3⁄4 3.6 46 46 3 837
PVI-42F 42 15790 1⁄4 1.2 52 52 1 492
PVI-42G 42 18100 3⁄8 1.8 52 52 1 1⁄2 563
PVI-42H 42 19900 1⁄2 2.4 52 52 2 620
PVI-42J 42 22775 5⁄8 3.6 52 52 3 710
PVI-42K 42 27000 3⁄4 6 52 52 5 840
PVI-48G 48 21870 1⁄4 1.8 58 58 1 1⁄2 477
PVI-48H 48 24070 3⁄8 2.4 58 58 2 525
PVI-48J 48 27550 1⁄2 3.6 58 58 3 601
PVI-48K 48 32670 5⁄8 6 58 58 5 713
PVI-48L 48 37400 3⁄4 9 58 58 7 1⁄2 815
PVI-54H 54 27750 3⁄8 2.4 60 60 2 426
PVI-54J 54 31720 1⁄2 3.6 60 60 3 487
PVI-54K 54 37650 3⁄4 6 60 60 5 578
PVI-54L 54 43118 7⁄8 9 60 60 7 1⁄2 662
PVI-54M 54 47426 1 12 60 60 10 726
PVI-60J 60 37120 3⁄8 3.6 66 66 3 430
PVI-60K 60 43940 1⁄2 6 66 66 5 509
PVI-60L 60 50325 3⁄4 9 66 66 7 1⁄2 583
PVI-60M 60 55420 7⁄8 12 66 66 10 642
PVI-60N 60 63445 1 18 66 66 15 735

 

Construction

Peerless' PVI Propeller Fan is built for your most demanding industrial applications. It offersfully-welded steel frames, heavy gauge mounting panels, and serviceable, adjustable drive components.

Propeller
Our panel-mount fans include a carbon steel blade assembly, dynamically balanced for efficient airflow at quiet volumes.

  • Carbon Steel Blades.
  • Carbon Steel Hubs.
  • Low Weight, High Efficiency Design.

Mounting Panel
Square, rigid steel mounting panels allow for either framed-in or surface mounting on walls or ceilings. Fan can be mounted in either a horizontal or vertical orientation.

  • Single-Piece Panel.
  • Pre-Drilled Mounting Holes.
  • Powder-Coated Finish.
  • Horizontal or Vertical Orientation.

Motor
All models utilize a continuous-duty, motor with selectable single or dual speed wiring. Single phase motors ¾ HP and below are resilient mounted ball or sleeve bearings. All others are rigid mounted ball bearings.

  • Continuous-Duty Motors.
  • Long Service Hour Rated.
  • Terminal Wiring Box Onboard.

Open Design
Open plug fans are designed for installation into existing field-erected or factory-built air handling units or plenum systems, pressurizing the air plenum in which the fan operates directly.

  • Space-Saving Design.
  • Eliminates Ducting Transitions into Fan Housing.
  • Flexible Duct Routing In Any Direction.

Drive System
V-Belt drive system allows for belt tension and sheave ratio (fan RPM) adjustment. All bearings are self-aligning, single row ball bearing pillow blocks with grease fittings.

  • Adjustable Speed and Belt Tension.
  • 200,000 Hour Average Bearing Life.
  • Welded Frame Maintains Belt Alignment.
Arrangements

Peerless' Propeller Fan PVI series is available in a Panel Mount format.

Panel Mount
Panel Mounting uses a flat sheet metal base as the frame for the fan's components. This square panel includes pre-drilled bolt holes, and is mounted by fastening to a flat wall, ceiling, or roof surface (check each model for acceptable orientations). The fan can be framed into an opening, surface-mounted, or mounted to a curb.

  • Belt Drive.
  • Permanently Lubricated Sealed Bearings.
  • Pre-drilled Mounting Holes.
Options

From personnel safety enhancements to explosion-proof environment ratings, Peerless' Propeller Fan PVI series has options to meet your most demanding industrial ventilation needs.

Discharge Shutters
To protect against weather and back-draft entry into the building through the fan housing, Discharge Shutters can be provided to mount onto the exterior building surface.

  • Hold Out Weather.
  • Corrosion-Resistant Construction.
  • Manual or Automatic Operation.

Discharge & Inlet Guards
For applications where the discharge or inlet side of the fan is exposed to personnel or nature, a heavy-duty expanded metal safety guard can be provided to restrict incidental access to the fan blades.

  • Heavy-Duty Expanded Metal Guard.
  • Improves Safety and Reliability.
  • Full Encloses the Fan Blades and/or Inlet.

Reverse Flow
Allowing the fan to serve as a make-up fan instead of an exhaust fan, a special reverse-flow blade and motor set can be configured for pulling air into the space.

  • Exhaust or Make-Up Airflow Options.
  • No Loss in Performance.
  • No Special Wiring or Controls Needed.

Spark Resistance
For applications where hazardous gases or other ignitable conditions exist, Peerless offers fully Spark-Resistant Construction and explosion-proof motors are available.

  • Hazardous Condition Protection.
  • Spark Resistant Materials.
  • Explosion Proof Motors.

Motors
Peerless can provide nearly any special motor specification, including multi-speed windings, stainless steel casings, washdown and other environmental ratings, inverter duty, explosion proof, IEC and other frame sizes, and more.

  • Any Compatible Motor Can Be Provided.
  • Domestic or International Frames.
  • Special Environment Ratings.

Downloads

Heritage Products Catalogs | Axial Propeller Fans

Axial Propeller Fans | PVI

Sign in to download

Fan Selector

Our online fan selection tool will help you identify a suitable model for your application's requirements and let you create a submittal.

Start Fan Selection

Contact our Sales Team

Mitarbeiterbild

Frank Mueller

Director of Sales - Americas

Phone:
+1.828.270.0343
Mobile:
+1.828.855.5446
E-Mail:
frank.mueller@punker.com

Mitarbeiterbild

T.J. King

Senior Sales Manager

Phone:
+1.828.622.7500
Mobile:
+1.828.206.1512
E-Mail:
TJKing@PeerlessBlowers.com

Mitarbeiterbild

Lisa Elkins

Inside Sales Manager

Phone:
+1.828.622.7500
E-Mail:
LElkins@PeerlessBlowers.com

Mitarbeiterbild

Heather Sawyer

Inside Sales Manager

Phone:
+1.828.622.7500
E-Mail:
HSawyer@PeerlessBlowers.com

Mitarbeiterbild

Gary Smith

Territory Sales Manager - Northeast

Phone:
+1.828.622.7500
Mobile:
+1.404.693.0052
E-Mail:
GSmith@PeerlessBlowers.com

Mitarbeiterbild

Joshua Meares

Area Sales Manager - Southwest

Mobile:
+1.980.342.0432
E-Mail:
joshua.meares@peerlessblowers.com

Mitarbeiterbild

Michael Burdukovsky

Area Sales Manager - Southeast USA

Phone:
+1.828.622.7500
Mobile:
+1.980.342.0941
E-Mail:
Michael.Burdukovsky@PeerlessBlowers.com

Mitarbeiterbild

Edgardo Rojas

Sales Representative - Mexico

Phone:
+52.442.595.8285
E-Mail:
edgardo.rojas@punker.com

Contact Us!

I hereby consent to the storage and processing of my personal data. I have read and taken note of the following information on the processing of my personal data and on data protection.